Managing NerveCenter - Contents -
Managing NerveCenter      Understanding NerveCenter

Managing NerveCenter

Understanding NerveCenter

What is NerveCenter?
How NerveCenter Manages Nodes
Defining a Set of Nodes
Detecting Conditions
Correlating Conditions
Responding to Conditions
Main NerveCenter Components
The NerveCenter Server
The NerveCenter Database
The NerveCenter User Interface
Role in Network Management Strategy
Standalone Operation
Using Multiple NerveCenter Servers
Integration with Network Management Platforms
Integration with NMPs for Node Information

Administering NerveCenter

Who Uses NerveCenter?
NerveCenter Login Rights
The Role of a NerveCenter Administrator

Running the NerveCenter Server

Running the NerveCenter Server on UNIX
Running the NerveCenter Server on Windows
Troubleshooting: Running the NerveCenter Server
UNIX will not start the NerveCenter Server
An alarm causes the NerveCenter Server to crash every time I start it
The NerveCenter Server does not start on Windows
I need to get a better idea of what the NerveCenter Server is doing on Windows. Can I

Connecting to the NerveCenter Server

Starting NerveCenter Administrator
Starting the NerveCenter Administrator on UNIX
Starting the NerveCenter Administrator on Windows
Connecting Administrator to a NerveCenter Server
Connecting Administrator to More Than One NerveCenter Server
Deleting a Name from the Administrator's Server List
Viewing Information about the Status of a NerveCenter Server
Disconnecting the Administrator from a NerveCenter Server
Troubleshooting: Connecting to the NerveCenter Server
UNIX will not start the NerveCenter Administrator
While trying to connect to a NerveCenter Server I get the message: The server did not
I misspelled a server name while trying to connect and now the misspelled name appears in

Managing the NerveCenter Server

Managing the NerveCenter Trap Source
Trap Source Overview
Changing the SNMP Trap Source
Working with NerveCenter Serial Numbers
Adding a Serial Number to a NerveCenter Server
Deleting an Old Serial Number from a NerveCenter Server
NerveCenter Rules for Managing Serial Numbers
Reconfiguring a NerveCenter Server from the Command Line
Troubleshooting: Managing the NerveCenter Server
When I try to connect to a NerveCenter Server it tells me: Number of allowed client
I need to make the same changes to several NerveCenter Servers
Importing imputil.ini caused unwanted changes to a NerveCenter Server

Managing NerveCenter Port Settings

NerveCenter's Client/Server Communication Port
Configuring the NerveCenter Server Connection Port
Changing the NerveCenter Administrator's Server Port
Changing the NerveCenter Client's Server Port
Configuring NerveCenter to Receive Inform Actions
Changing the Command Line Interface Port
Specifying SNMP Ports for NerveCenter
Troubleshooting: Managing NerveCenter Port Connections
The NerveCenter Server's communication port does not change when I selected Save in
A NerveCenter Server does not receive Informs sent by another NerveCenter Server
The NerveCenter Server's inform port did not change when I selected Save in NerveCenter

Managing Node Data

NerveCenter's Node List
Filtering Nodes
Filtering Using a Node's Capabilities
Filtering Using a Node's System Object Identifier
Filtering nodes using a Node's IP Address
Processing Traps from Unknown Nodes
Populating the Node List Initially
Populating NerveCenter's node list using your network management platform as a node data
Populating Using the IPSweep Behavior Model
Populating the Node List Manually
Maintaining the Node List
Synchronization with your network management platform
Adding Nodes Discovered from Traps
Adding and Deleting Nodes Manually
Troubleshooting: Managing node data
NerveCenter is not filtering a node by a capability
After setting an IP filter, a node that should be masked out still appears in the node list
Even though I have enabled Process Traps From Unknown Nodes, NerveCenter does not
NerveCenter does not recognize my network management platform as a valid source of node
NerveCenter is not receiving node data from my network management platform
The IPSweep behavior model will not work
The NerveCenter node list contains two nodes with the same address but different names
NerveCenter deletes a node I added manually
NerveCenter adds a node I deleted manually
I'm seeing several errors recorded in the application event log window stating that

Managing SNMP Settings

Specifying SNMP Poll Intervals for NerveCenter
Specifying SNMP Ports for NerveCenter
Overview of NerveCenter SNMP v3 Support
NerveCenter Support for SNMP v3 Security
NerveCenter Support for SNMP v3 Digest Keys and Passwords
Discovery and Initialization of SNMP v3 Agents
Configuring an SNMP v3 Agent for NerveCenter
Configuring an Initial User for Discovering an SNMP v3 Agent
SNMP Auto and Manual Classification Settings
How NerveCenter Classifies a Node's SNMP Version
When NerveCenter Classifies a Node's SNMP Version
Enabling Auto-classification
Setting a Maximum Classify Value
Setting the Maximum SNMP v3 Requests per Cycle
SNMP v3 Security Settings
Changing the SNMP v3 Key Passwords
Changing the NerveCenter SNMP v3 User Name and Context
SNMP v3 Operations Log
Signing a Log for SNMP v3 Errors Associated with Your Administrator
Signing a Log for SNMP v3 Errors Associated with a Remote Client or Administrator
Viewing the SNMP v3 Operations Log
SNMP Error Status

Managing NerveCenter Security

Managing Security on UNIX
Managing Security on Windows
Adding Users to a NerveCenter Installed on a Windows Workstation or Server
Adding Users to a NerveCenter Installed on a Windows Domain Controller
Troubleshooting: Managing NerveCenter Security
Users cannot connect to the server
Users in ncadmins or ncusers on UNIX cannot connect to the server
Anyone can connect to a Windows server
User can monitor alarms, but can't modify behavior models
User cannot connect to the NerveCenter Web client.

Managing NerveCenter Alarm Actions

Specifying an SMTP Server for Mail Notification
Configuring NerveCenter to Send Microsoft Mail
Configuring NerveCenter to Send Microsoft Mail while Running NerveCenter Server as a
Configuring NerveCenter to Send Microsoft Mail while Running NerveCenter Server as an
Setting Dialing Properties for Paging Notification on Windows
Setting Dialing Properties for Paging Notification on UNIX
Specifying Settings for Log Management
Troubleshooting: Managing Alarm Actions
NerveCenter is not sending SMTP mail notifications
Microsoft mail notifications are not being sent as NerveCenter
NerveCenter is not dialing pages correctly
The logs created by my behavior models are using too much disk space

Managing NerveCenter Web Integration

How to Start and Stop the NerveCenter Web Collector
Starting and Stopping the NerveCenter Web Collector in UNIX
Starting and Stopping the NerveCenter Web Collector in Windows

Managing the Database

Database Formats
Viewing Information about the Database
Backing up the Database
Backing up the Database Using the SerializeDB Application
Restoring the Database
Restoring the Database Using the SerializeDB Application
Restoring the Database from the Command Line
Transferring Data between Databases
ncdb2html.pl
Troubleshooting: Managing the NerveCenter Database
The server shut down gracefully, but event log said that the database was not found. Where
Running SerializeDB from the command line keeps failing
SerializeDB won't work from the application or the command line
The data in the database is not what was imported from the serialized file

Managing Management Information Bases (MIBs)

Sources of MIB Definitions
Definitions Compiled into the NerveCenter MIB
Definitions Not Compiled into the NerveCenter MIB
Definitions from other sources
Adding or Removing MIB Definitions
Compiling the NerveCenter MIB
Configuring NerveCenter to Use the New MIB
Troubleshooting: Managing Management Information Bases (MIBs)
A MIB won't compile
A MIB won't load

Error Messages

User Interface Messages
Error Messages
Action Manager Error Messages
Alarm Filter Manager Error Messages
Deserialize Manager Error Messages
Flatfile Error Messages
Inform NerveCenter Error Messages
Inform OV Error Messages
LogToDatabase Manager Error Messages
LogToFile Manager Error Messages
OpC Manager Error Messages
Poll Manager Error Messages
Protocol Manager Error Messages
PA Resync Manager Error Messages
Server Manager Error Messages
Trap Manager Error Messages
NerveCenter installation Error Messages (UNIX)
OpenView Configuration Error Messages (UNIX)

Troubleshooting NerveCenter

Common problems
The NerveCenter Server
NerveCenter's node list
Alarm actions
The NerveCenter database
Management Information Bases (MIBs)
Using Trace Counters to Troubleshoot NerveCenter
Alarm Action Counters
Database Counters
Inform Counters
Inform NerveCenter Counters
Log to Database Counters
Log to File Counters
Server Counters
Node Source Counters
OPC Msg Counters
Poll Counters
Trap Counters
Trigger Counters
Troubleshooting ASN.1 files
Use of characters
Period, underscore, and hyphen
Capitalization
Table construction
Duplicate type definitions
Object identifier format
Ignored IMPORT definitions

Controlling NerveCenter from the Command Line

NerveCenter UNIX Shell/DOS Prompt Commands
client
dbwizard
importutil
installdb
ipsweep
mibcomp
ncadmin
nccmd
ncserver
ncstart
ncstop
ovpa
paserver
semsopca
serializedb
trapgen
NerveCenter Command Line Interface
Entering a Single Command in a UNIX Shell or a DOS Prompt
Entering Multiple Commands in an Interactive Session
Running a script that contains one or more commands

Index


Managing NerveCenter Understanding NerveCenter
29 July 2003