Description
|
Section
|
---|
Do not change this section. |
[InstallShield Silent]
Version=v3.00.000
File=Response File |
Do not change this section. |
[Application]
Name=Open NerveCenter
Version=3.80.003
Company=OpenService |
Do not change this section. |
[DlgOrder]
Dlg0=Welcome-0
Count=5
Dlg1=AskDestPath-0
Dlg2=SelectFolder-0
Dlg3=SdAskOptions-0
Dlg4=SdFinish-0 |
By default, security is not configured. To configure security, comment out this section and uncomment the next section. |
;To say no to both security options
[SdAskOptions-0]
Component-type=string
Component-count=0
Result=1 |
By default, security is not configured. To configure security, comment out the previous section and uncomment this section.
Do not change the names of the groups. |
;To say yes to both security options
;[SdAskOptions-0]
;Component-type=string
;Component-count=2
;Component-0=NerveCenter Admins
;Component-1=NerveCenter Users |
Do not change this section. |
[Welcome-0]
Result=1 |
To install NerveCenter in another directory, or to specify a different HP OpenView directory, edit this section. |
[AskDestPath-0]
szTargetPath=c:\Program files\OpenService\NerveCenter\
szOVPAPath=c:\OpenView\
Result=1 |
Type your license key here. If you have more than one license key, separate them with semicolons (;). |
[License-0]
LicenseKey= |
Select the components you want to install. |
[AppSelection-0]
bInstallServer=1
bInstallClient=1
bInstallAdmin=1
bInstallPlatformIntegration=0
bInstallWebServerIntegration=1
bInstallOnlineBooks=0 |
Do not change this section. |
[ForceShutdown-0]
bForceShutdown=1 |
Edit this section to change platform adapter configuration options. |
[PlatformIntegration-0]
bOVPA=1
bPAServer=1
bUnicenterSupport=1
bNetcoolSupport=1
bPAServerAsService=1
bPAServerAutoStart=1 |
Edit this section to change web server configuration options. |
szWebServer=IIS ; Possible values (case sensitive): {IIS, PWS, NETSCAPE}
bRunAsService=1
bAutoStartService=1
bRestartWebServer=1
bForceInstall=1
szWebCollectorIP=*
nWebCollectorPort=32550 |
Edit this section to change server configuration options.
You can edit these options later with NerveCenter Administrator |
[ServerConfiguration-0]
MibName=NerveCtr.mib
bAutoStartService=1
nServerConnectionPort=32504
nSNMPRetries=3
nSNMPRetryInterval=10
nDefaultSNMPPort=161
bEnableDiscovery=0
Result=1
nTrapperConnPort=32506
nCLIConnPort=32507
nInformPort=32505
nDBRetryInterval=2 ; in minutes
nAlarmHistoryDepth=20
bNCNoSecurity=FALSE
bProcessUnknownTraps=True
bApplyAllMasksForEachTrap=True
bEnableSocketLogging=No |
Edit this section to change log management options. |
[ServerLogConfiguration-0]
nMaximumLogEntryAge=120
nMaximumLogFileSize=1024
nMaximumNumberOfRecords=1800
nLogDeletionPercentage=30
nMaxQueueDepth=10000 |
Edit this section to configure mail and pager actions.
You can edit these options later with NerveCenter Administrator |
[ActionsConfiguration-0]
;Sample Format
;ExchangeProfile=userjoe
;ExchangePassword=passwdjoe
;SMTPHost=smtphost
;PauseString=9,
ExchangeProfile=
ExchangePassword=
SMTPHost=
TouchPulse=Touch
PagerNumber=
PauseString=
Result=1 |
Edit this section if a network management platform is going to provide node information.
You can edit these options later with NerveCenter Administrator |
[NodeSourceConfiguration-0]
;Sample Formats:
;Host=sunny
;nHostPort=6024
;WantedCapabilities=capability1,capability2,capability3
;SystemObjectIds=OID1,OID2,OID3
;OpcHostName=norm
;OpcHostPort=6028
Host=
nHostPort=
Method=Manual
WantedCapabilities=
SystemObjectIds=
OpcHostName=
OpcHostPort=
Result=1
AckInforms=1 |
Edit this section to create IP filters that limit the nodes NerveCenter can detect and to enable Discovery.
You can edit these options later with NerveCenter Administrator |
[IPConfiguration-0]
;Sample Format
;SubnetMaskEx=Subnet1,Mask1:Subnet2,Mask2,Exclu2
; Choices below are none, all, filter
;IPDiscoverNodes=none
; Choices are 1 for True, 0 for False
;EnableDiscovery=
SubnetMaskEx=
IPDiscoverNodes=filter
EnableDiscovery=1 |
Edit this section to configure Inform hosts.
You can edit these options later with NerveCenter Administrator |
[NodeNotification-0]
;Sample Format
;NodeNotify1=host1 port1 EVENT_AND_SYMBOL minseverity1 prop1
;NodeNotify2=host2 port2 EVENT minseverity2 prop2
;ex: NodeNotify1=sunny 6024 EVENT_AND_SYMBOL 0
NodeNotify1=
Result=1 |
Edit this section to change NerveCenter's program group. |
[SelectFolder-0]
szResultFolder=NerveCenter
Result=1 |
Do not change this section. |
[SdStartCopy-0]
Result=1 |
Do not change this section. |
[SdFinish-0]
bOpt1=0
bOpt2=0
Result=1 |
Edit this section if you are installing if you do not want MSTrap as your trap service, that is, if you are installing OVPA or enabling SNMPv3 traps.
If you enable SNMP v3 traps, you must disable MS Trap service (bMSTrap=0). |
[TrapService-0]
bMSTrap=1 |
Edit this section to enable NerveCenter to receive SNMP v3 traps. |
[TrapConfig-0]
bNCV3Traps=0 |