Monitoring Your Network - Index -
OpenView Configuration Error Messages (UNIX)      Behavior Models Cookbook

Index

A

Action Manager error messages
Error Messages
Action Manager Error Messages
Action Router alarm action
Detecting Conditions
Action Router tool
Detecting Conditions
Administrator, NerveCenter
The NerveCenter User Interface
alarm actions
Detecting Conditions
Main NerveCenter Components
Action Router
Detecting Conditions
FireTrigger
Detecting Conditions
Alarm Filter error messages
Alarm Filter Manager Error Messages
alarms
Main NerveCenter Components
Main NerveCenter Components
filtering rules
Rules for Associating Filters with Alarms
node status state diagram
Detecting Conditions
state diagrams
Main NerveCenter Components

B

behavior models
How NerveCenter Manages Nodes
Main NerveCenter Components
predefined
Main NerveCenter Components
built-in triggers
Interpreting Alarm-Instance Information
CANNOT_SEND
Interpreting Alarm-Instance Information
ERROR
Interpreting Alarm-Instance Information
ICMP_ERROR
Interpreting Alarm-Instance Information
ICMP_TIMEOUT
Interpreting Alarm-Instance Information
ICMP_UNKNOWN_ERROR
Interpreting Alarm-Instance Information
list of
Interpreting Alarm-Instance Information
NET_UNREACHABLE
Interpreting Alarm-Instance Information
NODE_UNREACHABLE
Interpreting Alarm-Instance Information
PORT_UNREACHABLE
Interpreting Alarm-Instance Information
RESPONSE
Interpreting Alarm-Instance Information
SNMP_AUTHORIZATIONERR
Interpreting Alarm-Instance Information
SNMP_BADVALUE
Interpreting Alarm-Instance Information
SNMP_DECRYPTION_ERROR
Interpreting Alarm-Instance Information
SNMP_ENDOFTABLE
Interpreting Alarm-Instance Information
SNMP_GENERR
Interpreting Alarm-Instance Information
SNMP_NOSUCHNAME
Interpreting Alarm-Instance Information
SNMP_NOT_IN_TIME_WINDOW
Interpreting Alarm-Instance Information
SNMP_READONLY
Interpreting Alarm-Instance Information
SNMP_TIMEOUT
Interpreting Alarm-Instance Information
SNMP_TOOBIG
Interpreting Alarm-Instance Information
SNMP_UNAVAILABLE_CONTEXT
Interpreting Alarm-Instance Information
SNMP_UNKNOWN_CONTEXT
Interpreting Alarm-Instance Information
SNMP_UNKNOWN_ENGINEID
Interpreting Alarm-Instance Information
SNMP_UNKNOWN_USERNAME
Interpreting Alarm-Instance Information
SNMP_UNSUPPORTED_SEC_LEVEL
Interpreting Alarm-Instance Information
SNMP_WRONG_DIGEST
Interpreting Alarm-Instance Information
UNKNOWN_ERROR
Interpreting Alarm-Instance Information

C

CANNOT_SEND built-in trigger
Interpreting Alarm-Instance Information
CLI
The NerveCenter User Interface
Client, NerveCenter
The NerveCenter User Interface
command line interface
The NerveCenter User Interface
conditions
finding set of network
Detecting Conditions
network, detecting
Detecting Conditions
persistent network
Detecting Conditions
responding to network
Detecting Conditions
corrective actions
Detecting Conditions
correlating conditions
Detecting Conditions

D

database, NerveCenter
Main NerveCenter Components
defining
nodes, a set of
How NerveCenter Manages Nodes
Deserialize error messages
Alarm Filter Manager Error Messages
detecting condition persistence
Detecting Conditions
detecting conditions
Detecting Conditions
distributed NerveCenter Servers
Using Multiple NerveCenter Servers

E

ERROR built-in trigger
Interpreting Alarm-Instance Information
error status for SNMP v3 operations
SNMP Error Status

F

finding set of network conditions
Detecting Conditions
FireTrigger alarm action
Detecting Conditions
Flatfile error messages
Alarm Filter Manager Error Messages

I

ICMP_ERROR built-in trigger
Interpreting Alarm-Instance Information
ICMP_TIMEOUT built-in trigger
Interpreting Alarm-Instance Information
ICMP_UNKNOWN_ERROR built-in trigger
Interpreting Alarm-Instance Information
Inform NerveCenter error messages
Inform NerveCenter Error Messages
Inform OV error messages
Inform NerveCenter Error Messages
integration with network management platforms
Using Multiple NerveCenter Servers
Integration with NMPs for Node Information
integration with nmps for node information
Integration with NMPs for Node Information

L

Log to File error messages
Inform NerveCenter Error Messages
LogToFile Manager Error Messages
log, SNMP v3 operations
SNMP v3 Operations Log
SNMP v3 Operations Log
SNMP v3 Operations Log
SNMP v3 Operations Log
logging
Detecting Conditions
looking for a sequence of conditions
Detecting Conditions

M

main NerveCenter components
Main NerveCenter Components

N

NerveCenter
Action Router tool
Detecting Conditions
Administrator
The NerveCenter User Interface
Client
The NerveCenter User Interface
database
Main NerveCenter Components
distributed servers
Using Multiple NerveCenter Servers
nodes managing
How NerveCenter Manages Nodes
Server
Main NerveCenter Components
servers, multiple
Using Multiple NerveCenter Servers
what is
What is NerveCenter?
NerveCenter error messages
User Interface Messages
NerveCenter installation error messages
Trap Manager Error Messages
NerveCenter user interface
The NerveCenter User Interface
NerveCenter Web Client
The NerveCenter User Interface
NerveCenter's alarm console
Standalone Operation
NET_UNREACHABLE built-in trigger
Interpreting Alarm-Instance Information
network conditions
finding set of
Detecting Conditions
persistent
Detecting Conditions
responding to
Detecting Conditions
network conditions, detecting
Detecting Conditions
network management platforms
integration with
Integration with NMPs for Node Information
NODE_UNREACHABLE built-in trigger
Interpreting Alarm-Instance Information
nodes
defining a set of
How NerveCenter Manages Nodes
NerveCenter managing
How NerveCenter Manages Nodes
node status state diagram
Detecting Conditions
notification
Detecting Conditions

O

objects in the database
Main NerveCenter Components
OpC Manager error messages
LogToFile Manager Error Messages
OpenView
Trap Manager Error Messages
OpenView configuration error messages
OpenView Configuration Error Messages (UNIX)
OpenView event browser
Integration with NMPs for Node Information
Integration with NMPs for Node Information
operations log
SNMP v3 Operations Log
SNMP v3 Operations Log
SNMP v3 Operations Log
SNMP v3 Operations Log

P

PA Resync Manager error messages
PA Resync Manager Error Messages
Poll Manager error messages
LogToFile Manager Error Messages
PORT_UNREACHABLE built-in trigger
Interpreting Alarm-Instance Information
predefined behavior models
Main NerveCenter Components
properties
How NerveCenter Manages Nodes
Protocol Manager error messages
Protocol Manager Error Messages

R

responding to network conditions
Detecting Conditions
RESPONSE built-in trigger
Interpreting Alarm-Instance Information
role in network management strategy
Role in Network Management Strategy
routers
interface problems, alarm for
Detecting Conditions
rules for alarm filters
Rules for Associating Filters with Alarms

S

Server Manager error messages
Server Manager Error Messages
servers
alarm filtering rules
Rules for Associating Filters with Alarms
distributed NerveCenter
Using Multiple NerveCenter Servers
servers, multiple NerveCenter
Using Multiple NerveCenter Servers
severities
Main NerveCenter Components
smart polling
Detecting Conditions
SNMP v3
built-in triggers
Interpreting Alarm-Instance Information
Interpreting Alarm-Instance Information
Interpreting Alarm-Instance Information
SNMP v3 support
error status
SNMP Error Status
operations log
SNMP v3 Operations Log
SNMP v3 Operations Log
SNMP v3 Operations Log
SNMP v3 Operations Log
SNMP_AUTHORIZATIONERR built-in trigger
Interpreting Alarm-Instance Information
SNMP_BADVALUE built-in trigger
Interpreting Alarm-Instance Information
SNMP_DECRYPTION_ERROR built-in trigger
Interpreting Alarm-Instance Information
SNMP_ENDOFTABLE built-in trigger
Interpreting Alarm-Instance Information
SNMP_GENERR built-in trigger
Interpreting Alarm-Instance Information
SNMP_NOSUCHNAME built-in trigger
Interpreting Alarm-Instance Information
SNMP_NOT_IN_TIME_WINDOW built-in trigger
Interpreting Alarm-Instance Information
SNMP_READONLY built-in trigger
Interpreting Alarm-Instance Information
SNMP_TIMEOUT built-in trigger
Interpreting Alarm-Instance Information
SNMP_TOOBIG built-in trigger
Interpreting Alarm-Instance Information
SNMP_UNAVAILABLE_CONTEXT built-in trigger
Interpreting Alarm-Instance Information
SNMP_UNKNOWN_CONTEXT built-in trigger
Interpreting Alarm-Instance Information
SNMP_UNKNOWN_ENGINEID built-in trigger
Interpreting Alarm-Instance Information
SNMP_UNKNOWN_USERNAME built-in trigger
Interpreting Alarm-Instance Information
SNMP_UNSUPPORTED_SEC_LEVEL built-in trigger
Interpreting Alarm-Instance Information
SNMP_WRONG_DIGEST built-in trigger
Interpreting Alarm-Instance Information
standalone operation
Standalone Operation
state diagrams
link-down condition, detecting
Detecting Conditions
node status
Detecting Conditions
Understanding NerveCenter
status, error for SNMP v3 operations
SNMP Error Status

T

tools
Action Router tool
Detecting Conditions
transitions
Main NerveCenter Components
causing
Detecting Conditions
Trap Manager error messages
Trap Manager Error Messages
triggers
Main NerveCenter Components
built-in
Interpreting Alarm-Instance Information
built-in, list of
Interpreting Alarm-Instance Information

U

understanding NerveCenter
Understanding NerveCenter
UNKNOWN_ERROR built-in trigger
Interpreting Alarm-Instance Information


OpenView Configuration Error Messages (UNIX) Behavior Models Cookbook
29 July 2003