Release Notes - Fixes and Enhancements - NerveCenter 3.8.05 - Correcting Poll Conditions -
Previous: NerveCenter 3.8.06     Next: IfErrorRates

NerveCenter 3.8.05

Fixes and Enhancements in NerveCenter 3.8.05 describes all Fixes and Enhancements in NerveCenter 3.8.05.

Fixes and Enhancements in NerveCenter 3.8.05

Problem Description Win HP-UX Solaris

ERR11920/BUG11999 ncserver

ncserver exiting

OPV12048/BUG12231ovpa

Updates not being passed between NNM and NC3.8.05

SRV11650/BUG11651 ncserver

ncserver not polling nodes correctly

SRV12332/BUG12334 ncserver

Send Trap action does not pass the correct variables

SRV12340/BUG12341 ncserver

send trap action to $NCHostName ends up on all NC Hosts

SRV12335/BUG12336 ncserver

Memory growth in NC3.8.04

SRV12337/BUG12338 & BUG12239 ncserver

ovpa core dumping on NC3804 Solaris8

ERR11863 mibcomp

Problems with 3.8 mibcomp

ARC12416/ART12513 ncserver

Action Router usage yields CATAGORY 1 ERROR in messages file

GEN09610/BUG09817 & BUG12531 client

Cannot reset alarms to ground via GUI in 3721, 3722


Correcting Poll Conditions

Four polls have a mistake in the Poll condition which can overload your syslog or event manager.

This perl error is corrected in NerveCenter 3.8.06 if you perform a complete installation.

The upgrade process does not overwrite existing models, polls, etc., to preserve any modifications you may have made. In order to correct the Poll Conditions, you must manually edit the affected polls. You only need to edit these polls if you are upgrading from a previous version of NerveCenter.

The following polls have errors in the Poll Condition:

 
  To correct affected Poll Conditions:

  1. pollShaded.gif From the NerveCenter client's Admin menu, choose Poll List.

    The Poll List window is displayed.

  2. Select a poll from the poll list.

    Remember, the polls you need to correct are IfErrorRates, IfLoadRates, TcpConnectionMon, and TcpRetransStatus.

  3. Select the Open button

    NerveCenter displays the Poll Definition window.

  4. Select the Poll Condition tab.
  5. NerveCenter displays the Poll Condition page.
  6. Edit the Poll Condition as described in the following sections:
  7. Select the Save button to save your poll.


Previous: NerveCenter 3.8.06 Next: IfErrorRates