Behavior Models Cookbook - Vendor Models - CiscoTempCheck -
Previous: CiscoPwrSupplyCheck     Next: CpqDaLogDrvStat

CiscoTempCheck

Path: /model/vendors/cisco/cisco_temp_check.mod

This behavior model monitors the temperature status in a Cisco router. If a trap or a poll shows a problem, the alarm transitions to the TempWarning state which then polls the temperature status again for verification. If there is a problem, NerveCenter sends a 6008 Inform to the platform. Once the problem has been corrected, the alarm returns to ground.

Two additional alarms, CiscoTempCheck_LogToDB and CiscoTempCheck_LogToFile, are part of this model. When you enable these alarms, they perform a Log To Database or a Log to File alarm action, respectively, on each transition so that reports on temperature status can be produced.

Property

The following property must be in the property group for the nodes you want to monitor:

ciscoEnvMonTemperatureStatusEntry

Trigger Generators

Below is a list of the objects that generate triggers:

Events Sent to OpenView

The table below summarizes the events this behavior model sends to OpenView:

Event Name Inform Number Description

NC_Cisco_Temp

6008

An over-temperature condition has been detected for this device.


For complete information about events sent to OpenView, see the trapd.conf.txt file shipped with these behavior models residing in:

/model/vendors/cisco

For more information about integrating NerveCenter with OpenView, or the other NerveCenter-supported network manager platforms, refer to the book Integrating NerveCenter with a Network Management Platform.

Optional Customization

Below is a list of behavior model settings that you might want to customize to suit the requirements of your site.


Previous: CiscoPwrSupplyCheck Next: CpqDaLogDrvStat
Please send comments or corrections to Information Development
This file was last updated on 10 October 2000