Behavior Models Cookbook - Vendor Models - WfPwrSupplyCheck -
Previous: WfMemCheck     Next: WfTempCheck

WfPwrSupplyCheck

Path: /model/vendors/wellfleet/wf_pwr_supply_check.mod

This behavior model monitors the power supplies status in a Wellfleet router. If a poll shows a problem with any of the power supplies, the alarm transitions to the PowerSupplyWarning state which then polls the power supply status again for verification. If there is a problem, NerveCenter sends a 6507 Inform to the platform. Once the problem has been corrected, the alarm returns to ground.

Two additional alarms, WfPwrSupplyCheck_LogToDB and WfPwrSupplyCheck_LogToFile, are part of this model. When you enable these alarms, they perform a Log To Database or a Log to File alarm action, respectively, on each transition so that reports on power supply status can be produced.

Property

The following property must be in the property group for the nodes you want to monitor:

wfHwBase

Trigger Generators

Below is a list of the objects that generate triggers:

Events Sent to OpenView

The table below summarizes the events this behavior model sends to OpenView:

Event Name Inform Number Description

NC_Wellfleet_PowerSupply

6507

A power supply failure has been detected for this device.


For complete information about events sent to OpenView, see the trapd.conf.txt file shipped with these behavior models residing in:

/model/vendors/wellfleet

For more information about integrating NerveCenter with OpenView, or the other NerveCenter-supported network manager platforms, refer to the book Integrating NerveCenter with a Network Management Platform.

Optional Customization