White Papers
-
NerveCenter Integration with Micromuse Netcool/OMNIbus - How the Integration Components Interact -
For integration to occur, NerveCenter must be configured to send informs to Netcool/OMNIbus, and Netcool/OMNIbus must be configured to receive and process those informs. See NerveCenter Configuration Settings and Netcool/OMNIbus Configuration Settings for details.
The following must be running:
You may also want to start the Netcool/OMNIbus desktop applications, especially the Event List, to view messages and alerts.
Once the applications are running, the probe immediately creates a TCP socket and listens for connections from the NerveCenter platform adapter process. When the adapter sends a connection request, the probe confirms the connection.
The following illustrations show the components and their paths of communication for a simple integration configuration.
The Probe Connects with NerveCenter's Platform Adapter
When the two applications have established a connection, the probe relays the connection status to the Netcool Object Server, and the Netcool Event List viewer displays the status messages received from the Object Server. The following sample Event List window shows the messages received when the probe is started and connects with the Universal Platform Adapter (paserver.exe).
Event List Messages Upon Connection
Click the thumbnail above to view full-sized image.
After the probe and adapter establish their connection, NerveCenter can send informs to Netcool/OMNIbus. The NerveCenter Server issues an inform when a NerveCenter alarm transition occurs and the transition includes an inform action targeted for Netcool/OMNIbus. The Server sends the inform to the platform adapter, which passes the inform data to Netcool's NerveCenter probe.
NerveCenter Sends Informs to Netcool/OMNIbus
Click the thumbnail above to view full-sized image.
The probe receives the inform data and generates an identifier that uniquely identifies the event. The probe also converts the inform to an alert format that the Object Server can recognize and then forwards the alert to the Object Server.
The Object Server stores alerts in an alert table that is part of its active database. The Object Server can manipulate alerts by associating them into classes, filtering them, and assigning automated actions to them. Based on defined parameters, the Object Server determines the destination for each alert and forwards the information to the appropriate desktop applications.
The Event List displays the alerts forwarded from the Object Server, as seen in the following illustration.
Click the thumbnail above to view full-sized image.
A heartbeat message monitors the connection between the probe and the platform adapter. If the probe goes down or comes back up, the probe's new operational status appears immediately in the Netcool Event List. Once the probe comes back up, the platform adapter attempts to reestablish the connection every minute.
When the platform adapter goes down or comes back up, the following occur:
While NerveCenter alerts are being monitored in Netcool/OMNIbus, you can also view the original alarms in the NerveCenter Client or Web Client. The following illustration shows a sample Alarm Summary window in the NerveCenter Client.
NerveCenter Client Alarm Summary Window
Click the thumbnail above to view full-sized image.
The Client has filters that reduce the alarms to those matching specified property groups, severity levels, and IP subnets for associated servers. For more information about monitoring alarms, refer to NerveCenter's Monitoring Your Network online guide.
Previous: Components Required for Integration | Next: NerveCenter Configuration Settings |
Please send comments or corrections to Information Development | This file was last updated on 10 October 2000 |