Designing and Managing Behavior Models - Using Other Data Sources - NerveCenter's Built-In Triggers - Built-in Trigger Firing Sequence -
Previous: Ping Requests     Next: Matching Errors with Pending SNMP and Ping Requests

Built-in Trigger Firing Sequence

Table 26 shows the order in which NerveCenter fires built-in triggers.

NerveCenter Built-in Trigger Firing Sequence

If the First Trigger Fired
is an...
Then the Second Trigger Fired
Can Be an...
And the Third Trigger Fired
Can Be a...

ERROR

SNMP_ERROR

Specific SNMP built-in trigger


ERROR

ICMP_ERROR

None or, NET_UNREACHABLE, or NODE_UNREACHABLE, or PORT_UNREACHABLE


ERROR

SNMP_TIMEOUT

None


ERROR

ICMP_TIMEOUT

None


ERROR

CANNOT_SEND

None


RESPONSE

Specific non-built-in trigger or None

None


INFORM_CONNECTION_DOWN

None

None


INFORM_CONNECTION_UP

None

None


INFORMS_LOST

None

None


UNKNOWN_ERROR

None

None



Previous: Ping Requests Next: Matching Errors with Pending SNMP and Ping Requests
Please send comments or corrections to Information Development
This file was last updated on 10 October 2000